[Editorial Note: Insert the appropriate section number in the preceding reference] PART 7 PLACEMENT 7.01 EPS Geofoam fill shall be placed to the lines and grades shown in the plans and as directed by the Engineer. We may request cookies to be set on your device. ]P;gM Contains no formaldehyde or ozone-depleting HCFCs. % Buoyancy Force: 60.6 pounds per cubic foot (970 kilograms per cubic meter). geofoam @L@[Dt%300 ,5 endstream endobj startxref 0 %%EOF 130 0 obj <>stream A 200 mm (8 in) leveling pad shall be constructed over the prepared grade. Remove and legally dispose of construction debris from project site. Unless the project dictates otherwise, the blocks shall have a height of at least .91 m (36 inches), a width of at least 1.22 m (48 inches), and length of at least 2.44 m (96 inches). 3.03 The Engineer has the right to randomly sample the manufacturing plant. [This specification has been prepared for modification and use in the specifying of Geofoam for highway embankments and related uses. 7.1.2 Dimensional tolerances are described in Section 8, or as specified. 8. EPS 39, 2.5#, Type XIV in accordance with ASTM D6817: Minimum Density: 2.40 pounds per cubic foot (38.4 kilograms per cubic meter). Geofoam blocks with excessive damage (i.e. 2 0 obj At 10% Deformation: Minimum 60.0 psi, 7200 psf (345 kPa). TABLE 1: Physical Properties of EPS Geofoam TYPE - ASTM D6817EPS12EPS15EPS19EPS22EPS29EPS39EPS46Density, min., kg/m 3, ( lb/ft3 )11.2(0.70)14.4(0.90)18.4(1.15)21.6(1.35)28.8(1.80)38.4(2.40)45.7 (2.85)Compressive Resistance@ 1% deformation, min., kPa (psi)15(2.2) 25(3.6) 40(5.8) 50(7.3) 75(10.9) 103(15.0) 128 (18.6) Flexural Strength min., kPa (psi)69(10.0)172(25.0)207(30.0)276(40.0)345(50.0)414(60.0)517 (75.0)Elastic Modulus, min., kPA (psi)1500 (220)2500 (360)4000 (580)5000 (730)7500 (1090)10300 (1500)12800 (1860)Oxygen Index, min.,volume %24.024.024.024.024.024.024.0Geofoam should be considered combustible and should not be exposed to open flame or any source of ignition. Water-Resistant. For more information, office presentations, samples, examples of digital installation, or quotes, please contact us. Water Absorption per ASTM C272: 2.0 percent weight. N _rels/.rels ( j0@QN/c[ILj]aGzsFu]U ^[x 1xpf#I)Y*Di")c$qU~31jH[{=E~ Placement, 8. 4.04 The Certificate of Compliance shall include current inspection reports showing that the Geofoam manufacturer is in compliance with a UL follow-up service program for both flame and physical properties. Flexural Strength per ASTM C203: 140 psi minimum. Minimum Density: 1.80 pounds per cubic foot (28.8 kilograms per cubic meter). PART 5 PROTECTION 5.01 The Contractor shall prevent damage to the Geofoam blocks during delivery, storage, and construction. Unless otherwise specified in the contract, GeoFoam shall be cured for a minimum of 3 days before delivery and inspection. Concrete forms made of EPS29 can withstand a concrete pour height of 8' to 10' with no deformation depending upon rate of pour. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. Any Geofoam block that is exposed to sun light for more than six months shall be covered with an opaque material to prevent ultraviolet light degradation. Meets or exceeds the highest standards of ASTM C578 and ASTM D6817 for expanded polystyrene. Click to enable/disable _gid - Google Analytics Cookie. No thermal drift. Due to security reasons we are not able to show or modify cookies from other domains. <> EPS Geofoam for Use as Structural and Nonstructural Void Fill. E., Puyallup, WA 98375, Phone: 253-248-5995 Fax: 253 383-7100. Water Vapor Permeability: per ASTM E96: 2.5 maximum permeability per inch. No gaps greater than 20 mm (0.07ft) will be allowed on vertical joints. Press firmly into the rigid foam until the connector is flush with the surface. 7.04 Blocks placed in a row in a particular layer shall be offset .6 m (2.0 ft) relative to blocks placed in adjacent rows of the same layer as shown on the plans. The structure of this specification is in ten sections: 1. Copyright 2022 Universal Foam Products. For the number required, refer to Section 8 of this specification. Submittals, 5. At 5% Deformation: Minimum 13.1 psi, 1890 psf (90 kPa). Density, compression and geometry (dimensional tolerances) testing shall be conducted using 50.8 mm (2) cubes cut from representative blocks. 7.4 Combustibility Requirements - GeoFoam is an organic material and is combustible. They can be deleted as necessary. 5.03 Placement of embankment soil cover material will require special procedures and careful selection of appropriate construction equipment to prevent damage to the Geofoam fill. Where the total volume to be supplied amounts to 150 units or less, either a third party certificate or tightened inspection criteria of C-390 should be used as a basis for acceptance. You are free to opt out any time or opt in for other cookies to get a better experience. Section 02 30 00 - Subsurface Investigation. ASTM D6817 - Standard Specification for Rigid Cellular Polystyrene Geofoam. Buoyancy Force: 61.1 pounds per cubic foot (980 kilograms per cubic meter). Finished Geofoam on side slopes shall have a minimum of 0.61 m (2 ft) embankment cover. 5.04 Any damage to the Geofoam blocks resulting from the Contractors vehicles, equipment or operations, shall be replaced by the Contractor. Graphite Enhanced Polystyrene (GPS) SelterFoam. 7.5 Curing - GeoFoam must be cured at the manufacturing plant before shipment. Do not install products under environmental conditions outside manufacturer's recommended limits. There are components in this specification that may not be relevant for particular jobs. The finish-grade shall be smooth and free from holes and protruding objects. The surface of a layer of Geofoam blocks to receive additional Geofoam blocks shall be constructed with a variation in surface tolerance of no more than 15 mm (0.05 feet) in any 3 m (10 ft) interval. At 1% Deformation: Minimum 18.6 psi, 2680 psf (128 kPa). 6.3 The grade on which the Geofoam fill will be placed shall be graded to the elevations shown in the plans. Protection (including criteria for acceptable damage), 6. 9.3 Volume defect - volumetric damage of GeoFoam shall be limited to less than 1 percent of the volume of a block. Blocks in conformance with contract requirements can be used to make required fills. Water Absorption by total immersion per ASTM C272: 1.1 percent by volume, maximum. 9.2 Aerial defect - damage to load bearing GeoFoam surfaces shall be limited to less than 20 percent of the equivalent load bearing surface area of a single block. 5.05 Damage to Geofoam shall be corrected as follows: Slight damage less than .0283 m3 (1 ft3) may be left in place as is. E. Puyallup, WA 98375 800.248.5995 HYPERLINK "http://www.Insulfoam.com" www.Insulfoam.com HYPERLINK "mailto:geofoam@Insulfoam.com" geofoam@Insulfoam.com Specification for Insulfoam GF (Geofoam) [Items in italics are editorial comments that need to be removed when the specification is edited.] 10.2 Weight - determine the weight of selected full size units in accordance with Test Method D-1622 or as specified. It is a manufactured in block form and meets ASTM D6817, Standard Specification for Rigid, Cellular Polystyrene Geofoam. EPS Geofoam is available in a range of Types to provide control of structural integrity and cost effectiveness. At 5% Deformation: Minimum 8 psi, 1150 psf (55 kPa). Water Absorption, Maximum Total Immersion: 3 percent. Click on the different category headings to find out more. Section 32 39 33 - Artificial Rock Fabrications. Buoyancy Force: 60.0 pounds per cubic foot (960 kilograms per cubic meter). geofoam Often used in residential slab construction when hydronic heat is used. <> geofoam structural insulation insulfoam (Ex. Long-term stable R-Value, excellent dimensional stability, compressive strength and water resistant properties. 3.1. Regional Materials: Submit documentation of manufacturing plant location relative to project location if less than 500 miles (800 km). 11.1 Material that fails to conform to the above quality assurance criteria or specified requirements shall be rejected in writing promptly. hmo8J[8cVW Flexural Strength per ASTM C203: 25.0 psi minimum. Product Data: Submit manufacturer's product data and technical bulletins including materials, profiles, physical properties, and accessories for each product to be used, including: Preparation instructions and recommendations. Approved Material: Insulfoam Manufacturing Facility, Headquarters, 19727 57th Avenue. All blocks shall accurately fit relative to adjacent blocks. Conflicts between the manufacturer instructions and project documents shall be resolved in writing prior to construction. The location and type of connectors. Approved for use in certain NFPA 285 wall assembles. At 1% Deformation: Minimum 3.6 psi, 520 psf (25 kPa). PART 6 SUBGRADE PREPARATION 6.1 Clear and grub site. Dimensional Stability: per ASTM D2126: 2.0 maximum. Otherwise you will be prompted again when opening a new browser window or new a tab. Type VIII as per ASTM-C-578). The Geofoam shall be manufactured using modified expanded polystyrene. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding. <>>> In addition, computer generated stress-strain data and the accompanying curves shall be produced from compressive testing and supplied to the Engineer. At 5% Deformation: Minimum 35.0 psi, 5040 psf (241 kPa). Post-consumer is defined as any material that is recycled after its intended end-use while post-industrial recovery includes EPS facility scrap that is recycled but never served its intended purpose as a packaging material or other end-use application. ShelterFoam 100: High-performance high-density insulation consisting of a superior closed-cell, lightweight and resilient expanded polystyrene (EPS). Physical Requirements - as given in Table 1 and 2. EPS 46 3.0#, Type XV in accordance with ASTM D6817: Minimum Density: 2.85 pounds per cubic foot (45.7 kilograms per cubic meter). hbbd```b``:"d;dmWv>0~ _[$! STYROFOAM Brand Foam is a trademark of DuPont. Buoyancy Force: 59.5 pounds per cubic foot (950 kilograms per cubic meter). 10.4 Density - compute the density of test samples in accordance with Test Method D-1622. Geofoam blocks not meeting the damage criteria may be cut to eliminate the excessive damage and the remaining, undamaged, portion of the block may be used within the fill, provided the undamaged portion of the block meets all other design requirements. You can also change some of your preferences. ASTM-C-578). Each connector shall have a lateral holding strength of at least 27.22 kg (60 lbs) when tested with an EPS15 Geofoam. Insulfoam Manufacturing Facility, 3401 W. Cocopah Street, Phoenix, AZ 85009, Phone: 602-269-2272, Fax: 602-269-8402 Insulfoam Manufacturing Facility, 1155 Business Park Drive, Building A, Dixon, CA 95620, Phone: 707-678-6900, Fax: 707-678-2962 Insulfoam Manufacturing Facility, 4500 South Frontage Road, Lakeland, FL 33815, Phone: 863-688-8879, Fax: 863-682-1702 Insulfoam Manufacturing Facility, 501 S. Emerald Road, Tooele, UT 84074, Phone: 800-735-4621, Fax 800-769-6065 Insulfoam Manufacturing Facility, 12601 East 33rd Ave, Unit 110, Aurora, CO 80011, Phone: 303-366-7730, Fax: 303-366-7742 Insulfoam Manufacturing Facility, 628 Western Drive, Anchorage, AK 99501, Phone: 907-279-9407, Fax: 907-279-9011 Insulfoam Manufacturing Facility, 2000 Summit View Drive, Smithfield, PA 15478, Phone: 855-207-0087, Fax: 855-246-9936 Insulfoam Manufacturing Facility, 1057 Sunburst Lane, Mead, NE 68041, Phone: 402-624-6611, Fax: 402-624-2325 2.05 No product substitutions permitted. Warranty: Manufacturer's standard warranty that products will maintain performance values in ASTM D6817. Accordingly, materials shall be presented in lots of 151 or more for normal or tightened inspection, as required. 7.1 Inspection Requirements for on site quality assurance: 7.1.1 Minimum density shall be in accordance with Table 1, or as specified. Manufacturer must also have a UL classification in category BRYX. Quantity: As shown on the drawings, minimum 8 plates per block. If you refuse cookies we will remove all set cookies in our domain. hb```c``*d`a`x "@QS Click to enable/disable Google Analytics tracking. Store and handle materials in accordance with the manufacturers instructions to avoid damage. Ejfnz'|VCi}"3b_halNS'0]5XMm(SMSyk l]r-*'BpeY[S(`*-ELBW`Wpu}-,znYpifdAp.fm1T:@y%A5L+"f@]?paIlTO$cE$_ mDNP"'NeKKIY:_^} $K4PR"6i-^8tO{5.9"a[NZiwhe^?`%JJWPqhgC(aV'a83$P*qjenC?AY,)VdpL@H|"?G>ohXthV:\+b2K"K?iK&"3XI8*f9?f":)P w(PB*r==`A(u_|#6uj[Zk1k:8f nBJ`SOYPydRVA1I?QD~44(\PDFT@}Rc=w%}^45peu9R:SfS%5n(>}"Bz.{(.#* $AJ HNSPf5d_#)asQd If you do not want that we track your visit to our site you can disable tracking in your browser here: We also use different external services like Google Webfonts, Google Maps, and external Video providers. We are Southern Californias leading distributor of Geofoam manufactured by PAG Foam. No thermal drift. 3.02 Testing shall be conducted on samples taken from the first 76 m3 (100 yd3) of each Geofoam type manufactured for project delivery and at a rate of one test per 1147 m3 (1500 yd3) thereafter. If any block does not conform to the physical requirements it may be rejected by the Engineer. PART 8 CONNECTORS 8.01 Connectors shall be galvanized steel multi-barbed connectors or a urethane adhesive. eifs shapes precoated flats architectural eps insulation forte thermo drain flo foundation exterior polystyrene technical pdf resources geofoam structural insulation insulfoam PART 10 PAYMENT 10.01 Payment for the completed EPS Geofoam fill-work, which includes all equipment, labor and materials necessary to furnish and install the EPS Geofoam fill and connectors according to the plans and this specification, will be made in accordance with Section [xxx.xx] [Editorial Note: insert the appropriate section number in the preceding reference] for each of the following bid items: Type EPS12 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS15 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS19 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS22 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS29 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS39 Geofoam Lightweight Fill, per cubic meter (yard) Type EPS46 Geofoam Lightweight Fill, per cubic meter (yard) [Editorial Note: Delete the Types of Geofoam that are not used on this specific project from the list above.] At 1% Deformation: Minimum 15.0 psi, 2160 psf (103 kPa). Copyright 2022, Kingspan Insulation, LLC, All Rights Reserved, Polyisocyanurate (Polyiso) Insulation and EPS (Expanded Polystyrene), Pipe and Mechanical Insulation (-297F to +300F), Sheets for Insulated & Architectural Metal Panels, Pipe and Mechanical Insulation (up to +350F continuous). More than 118 million pounds of EPS were recycled during calendar year 2016. ' )n eps geofoam production The most commmonly used geofoam under slabs with heavier load requirements such as private garages and warehouse. Environmentally Friendly. Oxygen Index per ASTM D2863: 24.0 percent volume. Often used as void fill in green roof construction. Protect installed products and surface finishes from damage during construction. 4.02 Prior to the delivery of the EPS Geofoam blocks, the Contractor shall furnish the Engineer with a copy of manufacturers test reports or a third partys certified test report showing that the Geofoam blocks meet the physical properties and standards listed above in Table 1. Water Vapor Permeability: per ASTM E96: 4.0 maximum permeability per inch. Storage and handling requirements and recommendations. "Q&|ddl~(+C8hX%4n/urIWQ-/MLbpa5.G9_gV^&}[BO" i #Az*Z?E;WT.8G@bLbUbV4(;3 aIo=OyUBC iJU3 z, /|f\Z?6!Y_o]A PK ! The construction of roadways and retaining walls. 1.4 This specification does not purport to address all of the safety concerns, if any, associated with its use. No credit will be given for wasted material. At 1% Deformation: Minimum 5.8 psi, 835 psf (40 kPa). Certificates: Submit independent third party product certificates signed by manufacturer to demonstrate materials comply with specified performance requirements and ASTM D6817. Do not use where combined loads will exceed 1570 pounds per square foot with a safety factor applied.

Sitemap 17

eps geofoam specifications

eps geofoam specifications

coyote brown military boots safety toe You need to log in to enter the discussion
timotion lifting column
honeywell ct30a1005 troubleshooting